Comparison of sector field- and quadrupole-ICP-MS for the determination of DBT and TBT in sediment following GC separation

Download
  1. (PDF, 353 KB)
  2. Get@NRC: Comparison of sector field- and quadrupole-ICP-MS for the determination of DBT and TBT in sediment following GC separation (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1039/b304705a
AuthorSearch for: ; Search for: ; Search for:
TypeArticle
Journal titleJournal of Analytical Atomic Spectrometry
ISSN0267-9477
Volume18
Issue11
Pages13651370; # of pages: 6
AbstractA method is described for the accurate and precise determination of tributyltin (TBT) and dibutyltin (DBT) by species-specific isotope-dilution plasma-source mass spectrometry. Using gas chromatography (GC) for sample introduction and analyte separation, a performance comparison was made between sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) detection and quadrupole ICP-MS (qICP-MS) detection. Samples were extracted with acetic acid using open microwave digestion, derivatized with sodium tetraethylborate and extracted into isooctane. Mass bias correction was implemented based on the expected ratio of 120Sn/117Sn to that of the mean 120Sn/117Sn ratio calculated from the inorganic Sn peaks detected in all chromatograms. A more than 2-fold improvement in precision of calculated 120Sn/117Sn ratios was obtained for both TBT and DBT in standards using GC-SF-ICP-MS as compared to GC-qICP-MS. PACS-2 certified reference material marine sediment (NRCC, Ottawa, Canada) was used for method validation. Concentrations of 0.883 ± 0.013 and 1.126 ± 0.013 µg g−1 (mean and one standard deviation, n = 4) as tin were obtained for TBT and DBT, respectively, using GC-SF-ICP-MS detection, in agreement with the certified values of 0.98 ± 0.13 and 1.09 ± 0.15 µg g−1 (95% confidence interval), respectively. Concentrations of 0.883 ± 0.019 and 1.116 ± 0.014 µg g−1 (mean and one standard deviation, n = 4) as tin were obtained for TBT and DBT, respectively, using GC-qICP-MS detection. Slightly better precisions of 1.59–1.62% RSD for TBT and DBT in a test sediment were obtained using GC-SF-ICP-MS compared with 1.64–3.31% RSD obtained with GC-qICP-MS. Method detection limits (LODs, three times standard deviation) of 0.4 and 0.3 ng g−1 for TBT and DBT, respectively, were obtained using GC-SF-ICP-MS, based on processing a 0.5 g sample. As expected, these are superior to LODs of 0.9 and 1.0 ng g−1 obtained using GC-qICP-MS, arising from the three-fold enhancement in signal-to-background ratio obtained with the sector field machine.
Publication date
LanguageEnglish
AffiliationNRC Institute for National Measurement Standards; National Research Council Canada
Peer reviewedNo
Identifier10391186
NRC number99
NPARC number5763651
Export citationExport as RIS
Report a correctionReport a correction
Record identifier02e83795-7ff3-4afb-a4d8-b504a9c636a8
Record created2009-03-29
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)