Determination of the overall heat transmission coefficient (u-value) of vacuum glazing

  1. (PDF, 246 KB)
AuthorSearch for: ; Search for: ; Search for:
Proceedings titleASHRAE Transactions
ConferenceASHRAE Symposium: 01 June 1998, Toronto, Ontario
Issuept. 2
Pages19; # of pages: 9
SubjectHeat performance
AbstractThe heat flow through a 1m x 1m sample of vacuum glazing has been measured in two independent ways. One measurement method uses a guarded hot box to make a direct determination of overall heat-transmission coefficient under standard test conditions. The other method uses a small-area guarded hot plate (specially designed for this purpose) to measure the local radiative and (negligible) gas conductance between the glass sheets. This instrument is also used to validate calculations of the heat flow through the support pillars. The overall heat flow is then obtained by combining the contributions from these processes with those due to heat flow through the conducting edge seal. The results obtained with the two methods are in very good agreement for the same external conditions. These results provide the first independent validation of estimates of heat flow through vacuum glazing based on the five separate processes that contribute to this heat transfer.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
NRC number41907
NPARC number20331437
Export citationExport as RIS
Report a correctionReport a correction
Record identifier109b672b-8052-4e45-ae14-47b122923905
Record created2012-07-18
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)