Nuclear radiation effects on GaAs/AlGaAs quantum well infrared photodetectors

DOIResolve DOI: http://doi.org/10.1117/12.243034
AuthorSearch for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for:
TypeArticle
AbstractWe report on the experimental results of the effect of proton radiation on the performance of quantum well infrared photodetectors. A range of energies from 0.8 to 10 MeV and a range of fluences from 1012 to 1016 cm-2 were used. The detector performance are characterized by its responsivity becomes progressively worse with increasing fluence. For the same fluence, lower energy causes more damage to the detector.
PublisherSPIE
PlaceOrlando, FL, USA
AffiliationNational Research Council Canada; NRC Institute for Microstructural Sciences
Peer reviewedNo