Fire Resistance of Reinforced Concrete Columns

Download
  1. (PDF, 3 MB)
  2. Get@NRC: Fire Resistance of Reinforced Concrete Columns (Opens in a new window)
AuthorSearch for: ; Search for: ; Search for: ; Search for:
TypeArticle
ISSN0381-4319
Pages52
Subjectreinforced concrete; fire resistance; posts ( structures); design criteria; fire resistance data; fire resistance calculation methods; concrete walls; Walls; Concrete columns; beton arme; resistance au feu; poteau (ossature); critere de conception
AbstractThe fire resistance of square, reinforced concrete columns has been studied under both standard fire test conditions and under conditions that more closely resemble those encountered in practice, including column-structure interaction effects and realistic fire conditions. Based on calculated results, simple design rules are given for the fire resistance as a function of type of aggregate, column size, cover thickness to steel, amount of steel, design safety factor and equivalent buckling strength.
Publication date
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
IdentifierDBR-P-1167
NRC number23065
4146
NPARC number20358770
Export citationExport as RIS
Report a correctionReport a correction
Record identifier2c8ccd74-3c6e-437f-982c-78f2970ef1a4
Record created2012-07-20
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)