Method to calculate the fire resistance of circular reinforced concrete columns

Download
  1. (PDF, 631 KB)
  2. Get@NRC: Method to calculate the fire resistance of circular reinforced concrete columns (Opens in a new window)
DOIResolve DOI: http://doi.org/10.14359/2412
AuthorSearch for: ; Search for:
TypeArticle
Journal titleACI Materials Journal
ISSN0889-325X
Volume88
Issue1
Pages8491; # of pages: 8
SubjectConcrete columns
AbstractIn response to the growing need for an interest in the economic assessment of building-code provisions, the Institute for Research in Construction (IRC) of the National Research Council of Canada (NRCC) is developing analytical tools that should be of interest to design professionals. One such development is aPC-based model that can be used to assess the cost effectiveness of fire-safety provisions in buildings. At this stage, the risk-cost assessment model applies only to Canadian apartment buildings, but NRCC has a longer-term program to develop similar models for other types of buildings.
Publication date
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
IdentifierIRC-P-1951
NRC number34917
4201
NPARC number20358509
Export citationExport as RIS
Report a correctionReport a correction
Record identifier2fd3cc63-16d1-4ce9-ada5-b717a8b02c14
Record created2012-07-20
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)