Fire resistance behaviour of lightweight framed construction

Download
  1. (PDF, 450 KB)
AuthorSearch for: ; Search for:
TypeArticle
Conference3rd Structures in Fire Conference: 10 May 2004, Ottawa, Ontario
Pages119136; # of pages: 18
Subjectbehaviour, fire resistance, fire test, lightweight, moels, steel, wood; Walls; Floors
AbstractThis paper presents the results of a number of full-scale fire resistance tests conducted in accordance with the CAN/ULC-S101 standard on wall and floor systems. It describes the effects of a number of design parameters on the fire resistance performance of assemblies including: attachment of the gypsum board, insulation type, resilient channels, gypsum board thickness, number of gypsum board layers, stud arrangements, type of framing, resilient channel and framing spacing, sub-floor type and structural load. The paper also describes how the information gathered from this study will help in the selection of suitable assemblies and the models that have been developed to predict the fire resistance of lightweight assemblies.
Publication date
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
NRC number46891
16068
NPARC number20377400
Export citationExport as RIS
Report a correctionReport a correction
Record identifier370fbd08-0d62-408a-adff-8f995f13a621
Record created2012-07-24
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)