Calibration set-up for the marine dynamic test facility commissioning

AuthorSearch for:
TypeTechnical Report
Series titleLaboratory Memorandum
SubjectMDTF; Model submarine; Commissioning
AbstractIn October 1998, the new Marine Dynamic Test Facility was commissioned with the hydrodynamic testing of model submarine 'IMD497'. Further tests were performed in May 1999 with the same model. This report documents the apparatus and set-up for check calibrations of the model's dynamometer prior to the static test runs for the May 1999 commissioning. The positions of the model during these calibrations and the static runs are also verified.
Publication date
PublisherNational Research Council Canada. Institute for Marine Dynamics
PlaceSt. John's, NL
AffiliationNRC Institute for Ocean Technology; National Research Council Canada
Peer reviewedNo
NRC number5754
NPARC number8895847