The Effect of Mechanical Ventilation on the Air Leakage Characteristic of a Two-Storey Detached House

Download
  1. (PDF, 1 MB)
  2. Get@NRC: The Effect of Mechanical Ventilation on the Air Leakage Characteristic of a Two-Storey Detached House (Opens in a new window)
AuthorSearch for:
TypeArticle
Journal titleBuilding Research Note
ISSN0701-5232
Volume204
Pages26
Subjectmechanical ventilation; air leakages; residential facilities; Air and vapour barriers; Air flow/Wind pressure
AbstractAir change rates were measured in a two-storey detached house during the operation of various types of mechanical fresh-air ventilation systems. Two balanced systems (supply equals exhaust) and two exhaust-only systems were studied. Expressions were developed relating the house air change rate under winter conditions to the forced ventilation rate and the infiltration rate due to wind and temperature differences.