Experimental Studies on the Fire Endurance of High-Strength Concrete Columns

Download
  1. (PDF, 6 MB)
DOIResolve DOI: http://doi.org/10.4224/20386121
AuthorSearch for: ; Search for: ; Search for: ; Search for:
TypeTechnical Report
Series titleInternal Report, Institute for Research in Construction, National Research Council Canada; Volume 819
Physical description140 p.
SubjectHigh performance / High strength concrete; Concrete columns
AbstractExperimental studies were carried out to determine the fire endurance of high-strength concrete columns. The results of ten full-scale fire endurance tests are described in this report. The variables included column dimensions, concrete strength, type of aggregate in the concrete tie configuration, eccentricity of loading and load intenstiy. These studies were conducted as part of a research program aimed at studying the fire endurance of high-strength concrete columns.
Publication date
PublisherNational Research Council Canada
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
IdentifierIRC-IR-819
NRC number10146
NPARC number20386121