Fire Endurance Experiments on FRP-Strengthened Reinforced Concrete Columns

  1. (PDF, 1 MB)
DOIResolve DOI:
AuthorSearch for: ; Search for: ; Search for: ; Search for:
TypeTechnical Report
Series titleResearch Report, NRC Institute for Research in Construction; Volume 185
Physical description41 p.
SubjectFibre-reinforced polymers (FRP); Fibre-reinforced polymers (FRP); Concrete columns; Concrete
AbstractThree full-scale fire resistance tests were conducted at the National Research Council of Canada (NRC) in partnership with ISIS Canada and Fyfe Co. LLC, to investigate the behaviour of fibre reinforced polymer (FRP) wrapped (confined) reinforced concrete columns under exposure to the standard fire. Both columns were provided with a unique supplemental fire protection system. The results of fire endurance experiments on the three full-scale columns are described in this report. These tests were conducted as part of a collaborative research program, aimed at studying fire endurance of FRP-wrapped reinforced concrete columns. The test results suggest that, by providing proper fire insulation as described in this report, a 4-hour fire endurance rating can be achieved for loaded reinforced concrete columns strengthened with FRPwraps.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
NRC number16714
NPARC number20378290
Export citationExport as RIS
Report a correctionReport a correction
Record identifier69b9ab09-8130-4f52-a243-09b8d201f4c9
Record created2012-07-24
Record modified2016-10-03