Ice on Roofs

  1. (PDF, 303 KB)
  2. Get@NRC: Ice on Roofs (Opens in a new window)
AuthorSearch for:
Series titleCanadian Building Digest; no. 89
Physical description5 p.
SubjectRoofing; ice; pitched roofs; flat roofs; heating cables; ice dams; Snow and Ice loads
AbstractThis paper is concerned chiefly with ice on the eaves of sloping roofs. It describes conditions necessary for formation of ice dams, how roof leakage occurs, and design precautions or remedial measures necessary to limit ice formation and leakage.