The Electrical Heating Effect in Dunmore Sensors

Download
  1. (PDF, 1 MB)
  2. Get@NRC: The Electrical Heating Effect in Dunmore Sensors (Opens in a new window)
AuthorSearch for: ; Search for: ; Search for:
TypeArticle
Journal titleBuilding Research Note
ISSN0701-5232
Volume61
Pages11
SubjectHeating
AbstractHumidity sensors of the Dunmore type require that a voltage be applied to a thin hygroscopic film to determine the electrical resistance. This procedure results in an increase in film temperature through electric heating which, if not recognized, may lead to errors which are significant in precise measurement applications.