Measurements on posts and irises in circular waveguide

  1. (PDF, 1 MB)
DOIResolve DOI:
AuthorSearch for:
TypeTechnical Report
Physical description3 p.
AbstractThe susceptances of a centrally placed post and a centrally placed iris in circular waveguide were measured for the TE 11 mode. In both cases, experimentally determined values of shunt susceptance were compared with existing theoretical values for regular guide, and good agreement was found in the case of the iris. For a fixed aperture, the iris was rotated, and measurements were made of the susceptance of the iris and polarization of the transmitted wave.
Publication date
PublisherNational Research Council Canada
AffiliationNational Research Council Canada
Peer reviewedNo
NRC number2779
NPARC number21272365
Export citationExport as RIS
Report a correctionReport a correction
Record identifier86f4e879-3c84-4cde-9cf9-8d5706a79da3
Record created2014-11-25
Record modified2016-10-03
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)