Flanking paths between wood frame walls and floors using statistical energy analysis

Download
  1. (PDF, 358 KB)
AuthorSearch for: ; Search for:
TypeArticle
ConferenceInternational Congress on Acoustics: 20 June 1998, Seattle, Washington
Pages13891390; # of pages: 2
SubjectFlanking
AbstractFor the lightweight wood frame constructions considered in this paper, the dominant flanking path is shown to be from the floor decking to the wall below regardless of whether the wall is load-bearing or not. By comparison, the wall -- wall path is shown to be of negligible importance. A theoretical model is developed to predict transmission through the floor/wall joint. Measured and predicted results are in good agreement over the frequency range where flanking transmission is important.
Publication date
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
NRC number47681
13522
NPARC number20378566
Export citationExport as RIS
Report a correctionReport a correction
Record identifier87bcca3a-5870-4f55-918c-ba8afe10a29e
Record created2012-07-24
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)