Moisture Content and Dimensional Stability Measurements of the Insulation on a Protected Membrane Roof

Download
  1. (PDF, 543 KB)
  2. Get@NRC: Moisture Content and Dimensional Stability Measurements of the Insulation on a Protected Membrane Roof (Opens in a new window)
AuthorSearch for:
TypeArticle
Journal titleBuilding Research Note
ISSN0701-5232
Volume246
Pages6
SubjectRoofing; roofs; water barriers; polystyrene; moisture content; expansion contraction; Roofs; Couvertures
AbstractIn a field study carried out on a protected membrane roof insulated with a bead polystyrene, moisture contents of the insulation were sampled, using a coring device, over a period of about six years. The results showed wide variation in moisture content at different parts of the roof as well as an increase in moisture content with time. Final moisture content ranged from about 0.3 to 21.7% by volume and averaged 11.0% by volume.
Publication date
LanguageEnglish
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
IdentifierBRN-246
NRC number1762
NPARC number20378380