Experimental study and numerical modelling of the fire resistance of wood-stud wall assemblies

  1. (PDF, 293 KB)
AuthorSearch for: ; Search for: ; Search for:
ConferenceCSCE 30th Annual Conference: 05 June 2002, Montreal, Quebec
Pages110; # of pages: 10
AbstractThis paper presents the results from an experimental study on the behaviour of gypsum board- protected, wood-stud shearwall assemblies. The experimental study consisted of fire resistance tests on 12 full-scale wall assemblies. The factors investigated included effects of placement and type of shear membrane, insulation type, presence of resilient channels and load intensity on the fire resistance of such assemblies. The test results will be used to develop a model for predicting the fire resistance of wood-stud wall assemblies.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
NRC number45166
NPARC number20386079