Joint movement and sealant selection

  1. (PDF, 320 KB)
  2. Get@NRC: Joint movement and sealant selection (Opens in a new window)
AuthorSearch for: ; Search for:
Series titleCanadian Building Digest; no. 155
Physical description6 p.
Subjectjoints (junctions); sealants; jointing performance; Buildings
AbstractThe joint width should not be less than the minimum required for the sealant, allowing some flexibility in construction tolerances and counting on cyclical movements of structure. Authors discuss estimating of joint movement and installation temperatures. Examples given.
Publication date
PublisherDivision of Building Research. National Research Council Canada
AffiliationNRC Institute for Research in Construction; National Research Council Canada
NoteAussi disponible en français : Le mouvement des joints et le choix du matériau de calfeutrement