A bilateral comparison between NIST quantum-based power standard and NRC current-comparator-based power standard

DOIResolve DOI: http://doi.org/10.1109/CPEM.2012.6250872
AuthorSearch for: ; Search for: ; Search for: ; Search for:
Conference2012 Conference on Precision Electromagnetic Measurements (CPEM 2012), 2012-07-1 - 2012-07-6, Washington, DC, USA
Pages203204; # of pages: 2
SubjectCurrent-comparator; power bridge; power standard; quantum; uncertainty
AbstractThe results of a bilateral comparison on active/reactive power meter calibrations between the National Institute of Standards and Technology (NIST) and the National Research Council (NRC) will be presented. The comparison was implemented using a transfer standard consisting of a highly stable commercial sampling-type power/energy meter. The measurements were made at 120 V, 5A, 50 Hz and 60 Hz, at power factors of 1.0, 0.5 lead and lag, and 0.0 lead and lag.
AffiliationMeasurement Science and Standards; National Research Council Canada
Peer reviewedYes
NPARC number21269101
Export citationExport as RIS
Report a correctionReport a correction
Record identifier9424f9f5-6e74-4bc7-96a0-aebb58e31408
Record created2013-12-05
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)