Detection of chlorinated quinones using interdigitated electrodes coupled with capillary electrophoresis

Download
  1. Get@NRC: Detection of chlorinated quinones using interdigitated electrodes coupled with capillary electrophoresis (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1002/elps.200390117
AuthorSearch for: ; Search for:
TypeArticle
Journal titleElectrophoresis
Volume24
Issue6
Pages10161024; # of pages: 9
SubjectElectrophoresis; env
AbstractAn array of eight interdigitated microband gold electrodes (IDEs) has been developed together with electrophoretic separation for analysis of chlorinated hydroquinones (CIHQs) and benzoquinones (CIBQs). The IDE chip positioned very close to the separation capillary outlet served as an amplification/detection system without the requirement for frequent 'capillary-electrode' alignment. CIHQs, electrophoretically migrating to the IDE surface, were oxidized at +1.1 V by seven electrodes of the array and then detected by the remaining electrode, poised at -0.1 V. Conversely, CIBQs were detected at +1.1 V by the detecting electrode after having been reduced at the 7 adjacent electrodes poised at -0.1 V. There was an amplification effect on both the detecting electrode as well as the adjacent electrodes because of the recycle between CIHQs and CIBQs. The detecting 'amplification' current response was dependent on the potentials applied, the position of the detecting electrode on the array, the number of adjacent electrodes being used for recycling and the distance between the oxidative and reductive electrodes. Micellar electrokinetic chromatography (MEKC) separation of the analytes was achieved using 30 mM sodium dodecyl sulfate (SDS) with a detection limit in the range of 2-20 muM. In addition to a facile 'capillary-electrode' alignment, the important aspect described here was the capability of detecting through recycling a reduced compound (in the case of CIHQs) at a negative potential to circumvent fouling and electroactive interferences. An appealing feature was also the concurrent oxidation/reduction detection for each compound to ascertain peak assignment, as interfering compounds are less likely to exhibit the same oxidative/reductive characteristics and electrophoretic mobilities as the target analytes. (c) Biosciences Information Services.
Publication date
AffiliationNRC Biotechnology Research Institute; National Research Council Canada
Peer reviewedNo
NRC number45930
NPARC number3540099
Export citationExport as RIS
Report a correctionReport a correction
Record identifier958d8dbc-3007-4452-91a2-7338aeb653a9
Record created2009-03-01
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)