Fire Resistance of Beam-Slab Specimens : Experimental Studies

  1. (PDF, 1 MB)
DOIResolve DOI:
AuthorSearch for: ; Search for: ; Search for:
TypeTechnical Report
Series titleInternal Report, Institute for Research in Construction, National Research Council Canada; Volume 641
Physical description47 p.
SubjectFire; Fire Resistance; Performance of:
AbstractIn this report, the results of tests on three beam-slab specimens, constructed and tested at the Tianjin Fire Research Institute are described. The tests were carried out mainly for the purpose of evaluating the fire resistance of beams and slabs constructed of materials commonly used in China. The study variables included specimen composition, specimen dimension and materials.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
NRC number3463
NPARC number20375891
Export citationExport as RIS
Report a correctionReport a correction
Record identifier9d36bfcf-f5d1-4110-8dae-28e995256fcd
Record created2012-07-23
Record modified2016-10-03
Bookmark and share