Multivariate optimization of photochemical vapor generation for direct determination of arsenic in seawater by inductively coupled plasma mass spectrometry

Download
  1. (PDF, 562 KB)
  2. Get@NRC: Multivariate optimization of photochemical vapor generation for direct determination of arsenic in seawater by inductively coupled plasma mass spectrometry (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1016/j.aca.2015.10.020
AuthorSearch for: ; Search for: ; Search for: ; Search for: ; Search for:
TypeArticle
Journal titleAnalytica Chimica Acta
ISSN0003-2670
1873-4324
SubjectUV photochemical vapor generation; As; One point gravimetric standard addition and internal standardization; Inductively coupled plasma mass spectrometry
AbstractPhotochemical vapor generation (PVG) sample introduction coupled to inductively coupled plasma mass spectrometry (ICPMS) is described for the determination of As in seawater. A Plackett–Burman design (PBD) and central composite design (CCD) were employed to evaluate the significance of experimental variables relevant to the optimization of PVG-ICPMS detection. The impact of the saline matrix on the suppression of analyte signal was eliminated by use of a mixture of 20% (v/v) formic and 20% acetic acid (v/v) as the photochemical reductants. Optimized conditions yielded equivalent PVG generation efficiencies for As(III), As(V), monomethylarsonic acids (MMAs) and dimethylarsinic acids (DMAs), permitting direct and rapid determination of total arsenic in seawater without any other sample pre-treatment. Quantitation was accomplished using one point gravimetric standard addition along with a spike of 82Se internal standard to compensate for signal drift and fluctuation during analysis. The resulting method detection limit of 3 pg g−1 (3σ) provided a 15-fold improvement over that obtained using direct solution nebulization, and is comparable to that for conventional chemical hydride generation (HG)-ICPMS. Accuracy was demonstrated by analysis of two Certified Reference Materials (NASS-6 and CASS-5 seawater) with satisfying results characterized by precisions of 3.5% and 3.2% RSD for CASS-5 and NASS-6, respectively.
Publication date
LanguageEnglish
AffiliationMeasurement Science and Standards; National Research Council Canada
Peer reviewedYes
NPARC number21277071
Export citationExport as RIS
Report a correctionReport a correction
Record identifiera0bb79b7-af0e-4af3-b254-4930ee1f2a11
Record created2015-11-10
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)