Temperature, Relative Humidity, and Heat Requirements in an Electrically Heated Home, Sydney, N.S. - 1963

Download
  1. (PDF, 1 MB)
  2. Get@NRC: Temperature, Relative Humidity, and Heat Requirements in an Electrically Heated Home, Sydney, N.S. - 1963 (Opens in a new window)
AuthorSearch for:
TypeArticle
Journal titleBuilding Research Note
ISSN0701-5232
Volume53
Pages9
SubjectMoisture performance
AbstractIncreased interest in electric space heating in Nova Scotia in the past eighteen months led to the collection of data from a house in Sydney, N.S. The house, very similar to one in the Dartmouth project, was instrumented in January 1963 by the Atlantic Regional Station of the Division of Building Research in co-operation with the Eastern Light and Power Co. Ltd.