Report from Task 6 of MEWS Project : Experimental Assessment of Water Penetration and Entry into Wood-Frame Wall Specimens - Final Report

  1. (PDF, 2 MB)
DOIResolve DOI:
AuthorSearch for: ; Search for: ; Search for: ; Search for:
TypeTechnical Report
Series titleResearch Report, NRC Institute for Research in Construction; Volume 133
Physical description1 v. (various pagings) p.
SubjectMoisture performance
AbstractThe main emphasis of the MEWS project was to predict the hygrothermal responses of several wall assemblies that are exposed to North American climate loads, and a range of water leakage loads. Researchers used a method based on both laboratory experimentation and 2-D modeling with IRC's benchmarked model, hygIRC. This method introduced built-in detailing deficiencies that allowed water leakage into the stud cavity - both in the laboratory test specimens and in the virtual (modeling) ?specimens?- for the purpose of investigating water entry rates into the stud cavity and the drying potential of the wall assemblies under different climate loads. Since the project was a first step in investigating a range of wall hygrothermal responses in a parametric analysis, no field study of building characteristics was performed to confirm inputs such as water entry rates and outputs such as wall responsein a given climate. Rather, ranges from ?no water entry and no response' to ?too much water entry and too wet for too long' were investigated.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedNo
NRC number15275
NPARC number20386351
Export citationExport as RIS
Report a correctionReport a correction
Record identifiera77069ab-cc34-4c51-906b-6e07170b692e
Record created2012-07-25
Record modified2016-10-03
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)