System optimization for determination of cobalt in biological samples by ICP-OES using photochemical vapor generation

Download
  1. Get@NRC: System optimization for determination of cobalt in biological samples by ICP-OES using photochemical vapor generation (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1039/C6JA00069J
AuthorSearch for: ; Search for: ; Search for:
TypeArticle
Journal titleJournal of Analytical Atomic Spectrometry
ISSN0267-9477
1364-5544
Volume31
Issue8
Pages15901604
AbstractAn optimized photochemical vapor generation (PVG) approach for efficient synthesis of volatile cobalt species is described. Solutions containing Co(II) in a pH 3.3 medium of 50% formic acid were exposed to a source of deep UV (254 and 185 nm) radiation generated within a 19 W flow-through low pressure mercury discharge lamp. Following efficient phase separation, the analyte was transported to an ICP-OES system for detection at the 238.892 nm emission line of Co I. Several variables were investigated, including the type of UV lamp and gas–liquid separator, identity and concentration of the low molecular weight organic acid, solution pH, sample flow rate and exposure time to the UV irradiation as well as transport gas flow and mode of introduction of sample (continuous or segmented) to the ICP. In continuous mode, an optimum generation efficiency of 42 ± 2% was achieved with an irradiation time of 10 s, providing a 27-fold improvement in sensitivity compared to pneumatic nebulization and a limit of detection of 0.4 μg L−1 with a precision of 3% at 100 μg L−1. Direct analysis of acid digested biological tissues (NRC TORT-2 and TORT-3) was hampered by strong matrix interferences from the presence of nitrate and other ions which could be circumvented by longer irradiation time and sufficient dilution such that accurate analysis of real samples by the method of additions could be achieved while maintaining high generation efficiency.
Publication date
PublisherRoyal Society of Chemistry
LanguageEnglish
AffiliationMeasurement Science and Standards; National Research Council Canada
Peer reviewedYes
NPARC number23002548
Export citationExport as RIS
Report a correctionReport a correction
Record identifierc8fb2834-5a89-4468-a99a-f2cc19aeee31
Record created2017-11-29
Record modified2017-11-29
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)
Date modified: