Joints in conventional bituminous roofing systems

  1. (PDF, 431 KB)
  2. Get@NRC: Joints in conventional bituminous roofing systems (Opens in a new window)
AuthorSearch for:
Series titleCanadian Building Digest; no. 202
Physical description5 p.
SubjectRoofing; bituminous roofings; roof expansion joints; design; Roofs; Roofs
AbstractVarious types of membrane control joints are used in roofs to provide for expansion and contraction and to prevent splitting and excessive shrinkage at roof edges, but they frequently do not perform satisfactorily. The use of roof area dividers and expansion joints is discussed, and guidelines are given for the improved design and positioning of joints in a conventional roofing system.