The establishment of reactive power/energy standard at China electric power research institute and its comparison with NRC

DOIResolve DOI:
AuthorSearch for: ; Search for: ; Search for:
Proceedings title2012 Conference on Precision electromagnetic Measurements
Conference2012 Conference on Precision Electromagnetic Measurements (CPEM 2012), 2012-07-1 - 2012-07-6, Washington, DC, USA
SubjectCurrent-comparator; power bridge; power standard; uncertainty
AbstractA reactive power standard, based on the current comparator power bridge, established at CEPRI, for calibrating active/reactive power/energy meters under sinusoidal conditions is described. It allows calibration of active/reactive power and energy meters at voltages between 60 V to 600 V and currents between 0.1 A to 200 A, any power factor from zero lag through unity to zero lead, and test frequencies of 45 Hz to 65 Hz. The Type B uncertainty of the reactive power standard is estimated to be 30 μvar/VA at k = 2. A comparison of reactive power meter calibrations between CEPRI and NRC will also be presented and discussed, including the sources of errors and corresponding uncertainties.
Peer reviewedYes
NPARC number21269095
Export citationExport as RIS
Report a correctionReport a correction
Record identifierccfc8342-fb92-46e4-96e6-1a14b622e8d4
Record created2013-12-05
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)