Characterization of a 10V Programmable Josephson Voltage Standard and Comparison with a Hysteretic Josephson Standard

Download
  1. (PDF, 1 MB)
AuthorSearch for: ; Search for: ; Search for:
TypeArticle
Proceedings titleCPEM 2014 special issue of IEEE Transactions on Instrumentation and Measurement
ConferenceThe 2014 Conference on Precision Electromagnetic Measurements, August 24-29, 2014 , Rio de Janeiro
SubjectDC voltage; DC voltage calibration; Josephson junctions; programmable Josephson voltage standard; hysteretic Josephson voltage standard; Josephson system comparison; volt­ age measurements
AbstractA 10 V programmable Josephson voltage standard system has been installed at the National Research Council Canada. The current margins for the first Josephson step at either current polarity are greater than 1 mA. Measurements are made to establish the frequency offset and leakage resistance components of the uncertainty budget. Measurements are made to establish the frequency offset and leakage resistance components of the uncertainty budget...