Experimental study and modelling of thermal protection in liferafts using a thermal manikin and human subjects

  1. (PDF, 1 MB)
DOIResolve DOI: http://doi.org/10.4224/18074297
AuthorSearch for: ; Search for: ; Search for: ; Search for:
TypeTechnical Report
Series titleInstitute Report; no. IR-2009-01
Physical description11p.
SubjectThermal manikin; Marine Safety
AbstractExperiments were conducted in cold conditions (5°C water temperature and 5°C air temperature) to assess the thermal protection of a 16-person, SOLAS approved, commercially available liferaft using a thermal manikin and human subjects. The comparison tests included four cases – 1. Inflated raft floor; dry clothing (Idry); 2. Inflated raft floor; wet clothing (Iwet); 3. Uninflated raft floor; dry clothing (Udry); 4. Uninflated raft floor; wet clothing (Uwet). The results demonstrated equivalence in insulation between human subjects and a thermal manikin for all cases of comparison (Idry: Manikin 0.236 (m2°C)/W versus Human 0.224 (m2°C)/W; Iwet: Manikin 0.146 (m2°C)/W versus Human 0.145 (m2°C)/W; Udry: Manikin 0.174 (m2°C)/W versus Human 0.185 (m2°C)/W; Uwet: Manikin 0.101 (m2°C)/W versus Human 0.116 (m2°C)/W). The results also showed the repeatability of the thermal manikin tests (0.177 (m2°C)/W versus 0.171 (m2°C)/W in Udry baseline case; and 0.101 (m2°C)/W versus 0.104 (m2°C)/W in Uwet baseline case). The results indicated that the insulation of a closed cell foam floor is comparable to an inflated floor (0.236 (m2°C)/W compared to 0.221 (m2°C)/W and 0.236 (m2°C)/W for closed foam floor from manufacturer A and B respectively). TPA provided considerable additional insulation than all baseline cases. A test with a human subject wearing a TPA in the Uwet case showed an improvement of 48% over the baseline case. TPA provided more additional insulation than a wet suit in all test cases except Udry case. In Uwet case, the worst test condition, the insulation obtained by sitting on a lifejacket (0.149 (m2°C)/W) is less than wearing a TPA (0.158 (m2°C)/W). Both of these are better than sitting directly on an uninflated floor (0.104 (m2°C)/W) or a closed cell foam floor (0.129 (m2°C)/W). There is a significant decrease in insulation value sitting in 10 cm of water (0.05 (m2°C)/W). Two human subject tests show an insulation value of 0.079 (m2°C)/W and 0.081 (m2°C)/W respectively. A liferaft occupant heat loss model was developed and integrated with Defense R&D Canada’s Cold Exposure Survival Model to predict survival time. For Uwet case, the worst test condition, the survival time is 32 hours and functional time is 24 hours for those experimental conditions.
Publication date
AffiliationNRC Institute for Ocean Technology; National Research Council Canada
Peer reviewedNo
NPARC number18074297
Export citationExport as RIS
Report a correctionReport a correction
Record identifierd2acc1b4-e413-44bb-b2e4-94db01a87985
Record created2011-07-07
Record modified2016-10-03
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)