Demand-responsive lighting: a field study

  1. (PDF, 1 MB)
  2. Get@NRC: Demand-responsive lighting: a field study (Opens in a new window)
DOIResolve DOI:
AuthorSearch for: ; Search for:
Journal titleLeukos
IssueJanuary 3
Pages203225; # of pages: 23
Subjectdemand response, load shedding, energy management, comfort; Lighting
AbstractThis research investigated the tolerance of office workers for decreased illumination levels. The purpose was to assess the dimming that could be tolerated to reduce electricity demand during periods of grid stress without major inconvenience to workers. Participants (N=33) in an office laboratory were exposed to an initial baseline electric lighting level of 400 lx on their desktops. The electric lighting was dimmed smoothly over 10 seconds. During the dim, and for 30 seconds afterwards, the participants performed a computer-based proofreading task. The participants indicated if they had noticed the change, and whether the lighting conditions were acceptable. This was repeated over multiple trials, with dimming from 0 to 80%, and with or without daylight.
Publication date
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
NRC number53233
NPARC number20393373
Export citationExport as RIS
Report a correctionReport a correction
Record identifierd786c03a-237d-4e7e-b085-a645c9657dfa
Record created2012-07-26
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)