In vivo 1H MRS of human gallbladder bile at 3 T in one and two dimensions: Detection and quantification of major biliary lipids

Download
  1. Get@NRC: In vivo 1H MRS of human gallbladder bile at 3 T in one and two dimensions: Detection and quantification of major biliary lipids (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1002/nbm.3173
AuthorSearch for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for:
TypeArticle
Journal titleNMR in Biomedicine
ISSN0952-3480
Volume27
Issue10
Pages11921202; # of pages: 11
SubjectBile acid; Detection and quantifications; Human bile; In-vivo; L-COSY; Two-dimension; Presses (machine tools); bile acid; bile acid conjugate; cholesterol; glycine; lipid; proton; taurine; taurine conjugated bile acid; bile; contamination; gallbladder; in vivo study; magnetic field; metabolite; proton nuclear magnetic resonance; respiratory gated imaging
AbstractIn vitro 1H MRS of human bile has shown potential in the diagnosis of various hepatopancreatobiliary (HPB) diseases. Previously, in vivo 1H MRS of human bile in gallbladder using a 1.5 T scanner demonstrated the possibility of quantification of choline-containing phospholipids (chol-PLs). However, other lipid components such as bile acids play an important role in the pathophysiology of the HPB system. We have employed a higher magnetic field strength (3 T), and a custom-built receive array coil, to improve the quality of in vivo 1H MRS of human bile in the gallbladder. We obtained significant improvement in the quality of 1D spectra (17 healthy volunteers) using a respiratory-gated PRESS sequence with well distinguished signals for total bile acids (TBAs) plus cholesterol resonating at 0.66 ppm, taurine-conjugated bile acids (TCBAs) at 3.08 ppm, chol-PLs at 3.22 ppm, glycineconjugated bile acids (GCBAs) at 3.74 ppm, and the amide proton (-NH) arising from GCBAs and TCBAs in the region 7.76-8.05 ppm. The peak areas of these signals were measured by deconvolution, and subsequently the molar concentrations of metabolites were estimated with good accuracy, except for that of TBAs plus cholesterol. The concentration of TBAs plus cholesterol was overestimated in some cases, which could be due to lipid contamination. In addition, we report the first 2D L-COSY spectra of human gallbladder bile in vivo (obtained in 15 healthy volunteers). 2D L-COSY spectra will be helpful in differentiating various biliary chol-PLs in pathological conditions of the HPB system.
Publication date
PublisherWiley
LanguageEnglish
AffiliationNational Research Council Canada; Medical Devices
Peer reviewedYes
NPARC number21272689
Export citationExport as RIS
Report a correctionReport a correction
Record identifierdab61172-a37e-4892-91bb-997beeaf1937
Record created2014-12-03
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)