Calculation of the fire resistance of composite concrete floor and roof slabs

Download
  1. (PDF, 1 MB)
  2. Get@NRC: Calculation of the fire resistance of composite concrete floor and roof slabs (Opens in a new window)
AuthorSearch for:
TypeArticle
Journal titleFire Technology
ISSN0015-2684
Volume14
Issue1
Pages2845; # of pages: 18
SubjectRoofing; fire resistance; composite floors; concrete ( materials); roofs; calculations; Floors; Couvertures; resistance au feu; plancher mixte; beton (materiau); toiture; methode de calcul
AbstractA calculation method is described for the determination of the fire resistance of composite floor and roof slabs. Using this method, simple approximate formulas are derived for the calculation of the thermal fire resistance and minimum cover thickness to the steel of reinforced and prestressed concrete slabs, consisting of two layers of concrete, one lightweight and one normal weight. Comparison with test results shows good agreement between calculated and experimental fire resistances.