A procedure for deriving thermal transfer functions for walls from hot-box test results

  1. (PDF, 957 KB)
DOIResolve DOI: http://doi.org/10.4224/20377633
AuthorSearch for: ; Search for: ; Search for:
TypeTechnical Report
Series titleInternal Report, Institute for Research in Construction, National Research Council Canada; Volume 568
Physical description32 p.
SubjectHeat performance
AbstractA guarded hot-box is used t o determine the U-value of a wall specimen a t two different mean temperatures. With the hot side temperature held constant, the cold side temperature is varied at a constant rate during the transition between the two steady-state conditions. The results of this test are used to determine three time constants of the wall, which are then used to calculate the coefficients of the z-transfer function for that wall.