Spray-applied fire resistive coatings for steel building columns

  1. (PDF, 1 MB)
AuthorSearch for:
Proceedings titleASTM Special Technical Publication
ConferenceSymposium on Fire Resistive Coatings : the Need for Standards: 18 October 1982, Philadelphia, PA, USA
Pages4055; # of pages: 16
Subjectfire resistance; thermal properties; cement renderings; steel; posts (structures); heat transfer; mineral wool; steel columns; sprayed coatings; thermal conductivity; specific heat; heat transfer; numerical analysis; fire resistance; Buildings
AbstractThis paper describes the insulative value of spray-applied, cementitious and mineral-fiber fire resistive coatings for steel building columns. It presents results of high- temperature thermal property tests of the materials used as input to a two-dimensional heat flow analysis designed for predicting the fire resistance of hollow steel columns. The prediction is compared with actual fire test data. The influence of the thermal properties of the materials and their application thickness on fire resistance is discussed.