L'Effet du volume d'une salle sur la mesure des coefficients d'absorption du son

Download
  1. (PDF, 978 KB)
  2. Get@NRC: L'Effet du volume d'une salle sur la mesure des coefficients d'absorption du son (Opens in a new window)
AuthorSearch for: ; Search for:
TypeArticle
Journal titleCanadian Acoustics/Acoustique Canadienne
ISSN0711-6659
Volume12
Issue1
Pages3743; # of pages: 7
Subjectsound absorption; measurement; reverberation chambers; low frequencies (sound); volume; effect of room volume on sound absorption coefficients measurements; reverberation rooms; Acoustics; absorption acoustique; mesure; chambre reverberante; frequence grave; volume
AbstractMeasurements of sound absorption coefficients for 2 specimens in 4 similarly equipped reverberation rooms ranging in volume from 16 to 250 m[3] show significant differences at low frequencies. There is an approximately linear relation between the measured coefficient and the logarithm of the room volume. This could explain some of the differences in measured coefficients between laboratories.
Publication date
LanguageFrench
AffiliationNRC Institute for Research in Construction; National Research Council Canada
Peer reviewedYes
IdentifierDBR-P-1161
NRC number23034