Final report on CCM key comparison CCM.D-K2 : comparison of liquid density standards

Télécharger
  1. Obtenir@CNRC : Final report on CCM key comparison CCM.D-K2 : comparison of liquid density standards (Ouvre dans une nouvelle fenêtre)
DOITrouver le DOI : http://doi.org/10.1088/0026-1394/50/1A/07006
AuteurRechercher : ; Rechercher : ; Rechercher : ; Rechercher : ; Rechercher : ; Rechercher : ; Rechercher : ; Rechercher : ; Rechercher :
TypeArticle
Titre de la revueMetrologia
Volume50
Numéro1A Technical Supplement
Pages145; nbre. de pages : 45
RésuméThe results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10−5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database. The results can be used to link regional comparisons to this CCM key comparison.
Date de publication
Maison d’éditionIOP Science
Langueanglais
AffiliationScience des mesures et étalons; Conseil national de recherches Canada
Publications évaluées par des pairsOui
Numéro NPARC21268131
Exporter la noticeExport en format RIS
Signaler une correctionSignaler une correction
Identificateur de l’enregistrement0097c54e-c23f-4b6c-a882-356450c2a92e
Enregistrement créé2013-05-07
Enregistrement modifié2016-05-09
Mettre en signet et diffuser
  • Partagez cette page avec Facebook (Ouvre dans une nouvelle fenêtre)
  • Partagez cette page avec Twitter (Ouvre dans une nouvelle fenêtre)
  • Partagez cette page avec Google+ (Ouvre dans une nouvelle fenêtre)
  • Partagez cette page avec Delicious (Ouvre dans une nouvelle fenêtre)