Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin g concentrations in alpaca serum

Download
  1. Get@NRC: Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin g concentrations in alpaca serum (Opens in a new window)
DOIResolve DOI: http://doi.org/10.1111/jvim.12258
AuthorSearch for: ; Search for: ; Search for: ; Search for: ; Search for: ; Search for:
TypeArticle
Journal titleJournal of Veterinary Internal Medicine
ISSN0891-6640
AbstractBackground: Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. Objective: To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. Animals: One hundred and seventy-five privately owned, healthy alpacas. Methods: Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Results: Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. Conclusions and Clinical Importance: This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. © 2014 by the American College of Veterinary Internal Medicine.
Publication date
LanguageEnglish
AffiliationNational Research Council Canada (NRC-CNRC); NRC Institute for Biodiagnostics (IBD-IBD)
Peer reviewedYes
NPARC number21270791
Export citationExport as RIS
Report a correctionReport a correction
Record identifiere47dd969-1b1a-45e5-99e2-8391b6f8a66e
Record created2014-02-17
Record modified2016-05-09
Bookmark and share
  • Share this page with Facebook (Opens in a new window)
  • Share this page with Twitter (Opens in a new window)
  • Share this page with Google+ (Opens in a new window)
  • Share this page with Delicious (Opens in a new window)